  Datasheet File OCR Text:
  keysight technologies infiniium 9000 series oscilloscopes data sheet engineered for broadest measurement capability
02 | keysight | infiniium 9000 series oscilloscopes - data sheet table of contents if you havent purchased a keysight scope lately, why should you consider one now? ?????????????????????? 03 what makes the infiniium 9000 series the go-to scope for a whole range of test and debug challenges? ??????????????????????????????????????????????????????????????? 04 its three instruments in one ?????????????????????????????????????????????????????????????????????????????????????????????????????????????????????? 05 \ widest range of debug and compliance software applications: serial protocol-level ????????????????????????????????????????????????????????????????????????????????????????????????????????????????? 09 widest range of debug and compliance software applications: serial protocol and fpga ?????????????????????????????????????????????????????????????????????????????????????????????????????????? 10 widest range of debug and compliance software applications: serial physical-layer ????????????????????????????????????????????????????????????????????????????????????????????????????????????????? 11 widest range of debug and compliance software applications: infiniiscan and jitter analysis ??????????????????????????????????????????????????????????????????????????????????????????????????? 12 widest range of debug and compliance software applications: viewing and analysis ????????????????????????????????????????? ???????????????????????????????????????????????????????????????????????? 13 infiniium 9000 series applications and upgrades ?????????????????????????????????????????????????????????????????????????????????????? 14 keysight portfolio compare ????????????????????????????????????????????????????????????????????????????????? ??????????????????????????????????????? 15 keysight infiniium 9000 series oscilloscopes ????????????????????????????????????????????????????????????????????????????????????????????? 16 infiniium 9000 series performance characteristics ??????????????????????????????????????????????????????????????????????????????????? 19 infiniium 9000 series ordering information ???????????????????????????????????????????????????????????????????????????????????????????????? 27 upgrades ?????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????????? 29 keysight oscilloscopes ?????????????????????????????????????????????????????????????????????????????????? ?????????????????????????????????????????????? 30
03 | keysight | infiniium 9000 series oscilloscopes - data sheet if youre like most engineers, you never know what your next project will demand from you ? you need an oscilloscope that can adapt to a wide variety of debug and test challenges ? thats why we designed our new infiniium 9000 series oscilloscope to meet a full range of needs ? first we built in the powerful features youd expect in any infiniium scope ? then we engineered the scope for the broadest measurement capability, so it would be the most indispensable tool in your arsenal ? model analog bandwidth analog sample rate 4-channel/2-channel standard memory 4-channel/2-channel scope channels logic channels dso9064a 600 mhz 5 gsa/s/10 gsa/s 20 mpts/40 mpts 4 C mso9064a 600 mhz 5 gsa/s/10 gsa/s 20 mpts/40 mpts 4 16 dso9104a 1 ghz 10 gsa/s/20 gsa/s 20 mpts/40 mpts 4 C mso9104a 1 ghz 10 gsa/s/20 gsa/s 20 mpts/40 mpts 4 16 dso9254a 2.5 ghz 10 gsa/s/20 gsa/s 20 mpts/40 mpts 4 C mso9254a 2.5 ghz 10 gsa/s/20 gsa/s 20 mpts/40 mpts 4 16 dso9404a 4 ghz 10 gsa/s/20 gsa/s 20 mpts/40 mpts 4 C mso9404a 4 ghz 10 gsa/s/20 gsa/s 20 mpts/40 mpts 4 16 the infiniium 9000 series offers bandwidths up to 4 ghz ? each model, equipped with a large 15 xga lcd display, comes in a whisper-quiet package that is just 9 (23 cm) deep and weighs only 26 pounds (11 ? 8 kg ) ? there is no better way to experience the superiority of the infiniium 9000 series scopes than to see it ? contact keysight technologies, inc ? today to request an evaluation ? there is no better way to experience the superiority of the infiniium 9000 series scopes than to see it ? contact keysight today to request an evaluation ? or visit: www.keysight.com/find/9000 if you havent purchased a keysight scope lately, why should you consider one now?
04 | keysight | infiniium 9000 series oscilloscopes - data sheet its three instruments in one 1 ? scope: the powerful features of our infiniium series oscilloscopes coupled with superior specifications give you precise signal representation ? 2 ? logic analyzer: fast deep-memory digital channels let you see critical data values and timing relationships ? 3 ? protocol analyzer: the worlds first scope-based protocol viewer with multi-tab viewing ? quickly drill and move between protocol and physical layers ? it offers the widest range of debug and compliance application software need accurate answers to your measurement questions? the infiniium 9000 series offers the largest range of application- specific software for debug, analysis and compliance testing ? which application is right for you? take a look at the possibilities on pages 7 to 12 ? its sized to fit your environment limited bench space? it has a small footprint and thin profile height: 12 ? 9 (33 cm); width: 16 ? 8 (43 cm); depth: just 9 (23 cm) need to share the scope? its light weight: 26 lbs ? (11 ? 8 k g) need to see lots of signals? it has the biggest screen: 15 (23 cm) xga what makes the infiniium 9000 series the go-to scope for a whole range of test and debug challenges?
05 | keysight | infiniium 9000 series oscilloscopes - data sheet responsive deep memory with standard 20 mpts/ch, and up to 1 gpts/ch of memory, you can capture long time periods while retaining fast sample rates ? fast update rates mean your scope stays responsive with deep memory on, ensuring precise representation of analog signals ? advanced triggering advanced triggers are essential when you are investigating suspected problems ? infiniium offers a full range of advanced triggers to help you isolate and capture the condition you need to characterize ? the 9000 series simplifies trigger setups by using intuitive dialog boxes with descriptive graphics ? up to 4 ghz bandwidth and 20 gsa/s high sample rates guarantee youll see a precise representation of the analog characteristics of signals youre testing ? mask tests, histograms and a wide variety of functions such as the gated ffts in the above image provide deep signal analysis ? 1 ? o scilloscope high-performance scope channels ensure superior viewing of signals under test ? all models incorporate a powerful, feature- packed infiniium oscilloscope with responsive deep memory ? its three instruments in one
06 | keysight | infiniium 9000 series oscilloscopes - data sheet 2 ? logic analyzer mso models add 16 high-speed timing channels with standard 128 mpts digital memory, allowing you to retain fast 2 gsa/s sample rates over long periods of time ? use the timing channels to evaluate control signal relationships and data buses up to 16 bits wide ? use symbols to more quickly interpret waveforms ? designing with xilinx fpgas? use the fpga dynamic probe for rapid internal fpga measurements ? using i2c, spi, rs-232, or low- or full- speed usb? use the digital channels to acquire and decode these buses, preserving analog channels for other time-correlated measurements ? drag and drop measurements its simple: drag an icon from the measurement bar and drop it on the cycle you want to measure ? you can make up to ten measurements on your waveforms ? all of the measurements appear at the bottom of the display with statistics and are color-coded to the channel you are measuring ? 1 ? o scilloscope (continued) its three instruments in one (continued)
07 | keysight | infiniium 9000 series oscilloscopes - data sheet digital and mixed-signal trigger trigger on and display individual signals or buses ? with precise time-correlation between analog and digital signals, confidently trigger across any combination of analog and digital signals simultaneously ? industrys only segmented memory for both analog and digital channels capture short bursts without consuming memory during periods when the trigger condition is not met ? keysight is the only vendor that supports segmented memory capture on both analog and digital channels ? waveform and listing windows view buses as waveforms or easily follow events in the listing window expandable to the entire display ? a blue tracking marker provides time-correlation between waveform and listing displays ? its three instruments in one (continued) 2 ? logic analyzer (continued)
08 | keysight | infiniium 9000 series oscilloscopes - data sheet quickly move between physical and protocol layer information using the time-correlated tracking marker ? display protocol content using waveform symbols and the industrys first multi-tab protocol viewer ? the packets tab shows a high level view of the packet over time ? protocol-level triggering makes it easy to isolate events with pinpoint accuracy ? use any combination of analog or digital channels for serial protocol decode, with up to four buses decoded simultaneously ? header tab shows packets in a databook format ? hovering on any tab reveals additional detail ? 3 ? p rotocol analyzer does your design include a serial bus that is a key point for testing or debugging? add protocol analysis capability to your scope for: C can C pcle C digrf C flexray C rs-232/uart C i 2 c C sata C jtag C spi C lin C usb C mipi d-phy C 8b/10b its three instruments in one (continued)
09 | keysight | infiniium 9000 series oscilloscopes - data sheet trigger and view on-screen serial decode of i 2 c packets ? trigger on and decode rs-232/uart transmission ? trigger on and decode can, lin and flexray serial packets ? import bsdl files and decode jtag scan chain activity ? i 2 c/spi serial trigger and decode (n5391b or option 007 on newscope purchases) this application displays real-time time-aligned decode of i 2 c and spi serial buses ? hardware-based triggering means triggering reliably, even on the most infrequent events ? this application works on all models and can use any combination of scope or logic acquisition channels ? for more information: www.keysight.com/ind/9000_i 2 c-spi rs-232/uart serial decode and trigger (n5462b or option 001 onnew scope purchases) this application eliminates the need to manually decode bus trafic ? using data captured on the scope or logic channels, the application lets you easily view the information sent over an rs-232 rs-422, rs-485 or other uart serial buses ? display real-time time-aligned decode of transmit and receive lines ? hardware-based triggering means triggering reliably, even on the most infrequent events ? this application works on all models and can use any combination of the scope or logic acquisition channels ? for more information: www.keysight.com/find/9000_rs-232 can, lin and flexray triggering and decode (n8803b or option 008 on new scope purchases) trigger on and view both protocol layer information and physical layer signal characteristics for can, lin and flexray buses ? numerical decode values are automatically displayed and synchronized below the captured signal or seen in protocol viewer ? hardware-based triggering for can and lin means triggering reliably, even on the most infrequent events ? flexray uses software-based protocol triggering ? this application works on all models and can use any combination of scope or logic acquisition channels ? for more information: www.keysight.com/find/9000_can jtag (ieee 1149 ? 1 ) triggering and decode (n8817b or option 042 on new scope purchases) this application displays real-time time-aligned decode of jtag (ieee 1149 ? 1 ) tdi and tdo signals ? the application eliminate the dificult task of manually determining jtag tap controller states, instruction and data register decode, and lags error conditions ? the application includes scan chain description features including the ability to import ? b sdl iles for each device and displays device names and opcodes in the protocol listing ? this application works on all models and can use any combination of scope or logic acquisition channels ? for more information: www.keysight.com/find/9000_jtag widest range of debug and compliance software applications: serial protocol-level
10 | keysight | infiniium 9000 series oscilloscopes - data sheet trigger on and decode usb packets ? trigger on and decode mipi packets ? trigger on and decode sata serial packets ? trigger on and decode pcie serial packets ? usb serial trigger and protocol viewer (n5464b or option 005 on new scope purchases) trigger on and quickly view usb packets, payload, header and detail information ? powerful time-correlated views of waveform and symbol, to the bit level, make it easy to isolate communication faults to logic or analog sources ? usb hardware-based triggering means triggering reliably, even on the most infrequent events ? low and full-speed usb protocol is supported on digital and scope channels of all models ? high-speed usb protocol is supported on scope channels of 1 ghz, 2 ? 5 g hz and 4 ghz models ? f or more information: www.keysight.com/find/9000_usb mipi ? d-phy sm serial decode and trigger (n8802b or option 019 on new scope purchases) this application eliminates the need to manually decode bus traffic ? using data captured on the scope, the application lets you easily view the information sent over mipi serial buses ? the application also enables software-based protocol triggering ? this application works on all 4 ghz models and can use any combination of the scope channels ? for more information: www.keysight.com/find/n8802b pci express ? serial trigger and protocol viewer (n5463b or option 006 on new scope purchases) this application provides protocol-level triggering and viewing of a pcie ? lane ? quickly view packets, payload, header, and detail information ? powerful time-correlated views of waveform, symbol, character, link and transaction layer packet data down to the bit level make it easy to isolate communication faults to logic or analog sources ? trigger on and view crc, 8b/10b and disparity errors ? hardware-based triggering for pcie means triggering reliably, even on the most infrequent events ? this application is supported on scope channels of 4 ghz models ? for more information: www.keysight.com/find/9000_pci sata triggering and decode (n8801a or option 038 on new scope purchases) trigger on and view both protocol layer information and physical layer signal characteristics for sata 1 (1 ? 5 g b/s) ? numerical decode values are automatically displayed and synchronized below the capture signal or seen in protocol viewer ? this application enables software-based protocol triggering ? t his application works on 4 ghz and can use any combination of scope channels ? for more information: www.keysight.com/find/n8801a widest range of debug and compliance software applications: serial protocol and fpga
11 | keysight | infiniium 9000 series oscilloscopes - data sheet check for usb compliance ? test ddr memory ? validate ethernet compliance ? check for mipi compliance ? usb 2 ? 0 c ompliance testing (N5416A or option 029 on new scope purchases) quickly determine usb compliance with this usb-if recognized solution ? a setup wizard guides you through test selection and coniguration ? this application is usb-if approved and supported on all 2 ? 5 g hz and 4 ghz models ? for more information: www.keysight.com/find/9000_usb-compliance ddr1 and lpddr/ddr2 and lpddr2/ddr3 compliance testing (u7233a/n5413b/u7231b or options 031/032/033 on new scopepurchases) or n5459a opt 001 for all memory applications quickly and easily evaluate and characterize your memory designs ? automated testing based on jedec speciications saves time ? the application also includes additional debug and compliance capabilities ? this application is supported on all models ? however, the ddr technology you are using may dictate the minimal bandwidth required for your scope ? for more information: www.keysight.com/find/9000_ddr ethernet compliance testing (n5392b or option 021 on new scope purchases) perform a wide range of electrical tests for 10-, 100-, and 1000-base-t systems ? an n5395c test ixture and n5396a jitter test cable speed compliance testing ? this application is supported on all 600 mhz and higher bandwidth models ? for more information: www.keysight.com/find/9000_ethernet mipi compliance testing (u7238b or option 035 on new scope purchased) quickly validate your embedded d-phy data link for csi and dsi architectures ? this software performs a wide range of tests required for meeting mipi d-phy physical layer requirements ? this application is supported on analog channels of all 4 ghz models ? for more information: www.keysight.com/find/u7238b widest range of debug and compliance software applications: serial physical-layer
12 | keysight | infiniium 9000 series oscilloscopes - data sheet identify signal integrity issues with infiniiscan zone C qualify triggering ? conduct jitter analysis ? analyze jitter plus rj/dj separation ? ezjit complete ? infiniiscan event identiication (n5415b or option 009 on new scope purchases) rapidly trigger on complex events and identify signal integrity issues ? this innovative software quickly scans through thousands of acquired waveform cycles and isolates anomalous signal behavior ? up to eight zones across channels are available ? this application is supported on all models ? f or more information: www.keysight.com/find/infiniiscan ezjit analysis software (e2681a or option 002 on new scope purchases) quickly characterize and evaluate most commonly needed jitter measurements, including cycle-cycle, n-cycle, period, time-interval, error, setup and hold time, histograms, measurement trending and jitter spectrum ? this application is supported on all models ? f or more information: www.keysight.com/find/ezjit ezjit plus analysis software (n5400a or option 004 on new scopepurchases ? to upgrade from ezjit to ezjit plus, order n5401a ? ) ezjit plus adds additional compliance views and an expanded measurement setup wizard to simplify and automate rj/dj separation for testing against industry standards ? this application is supported on all models ? f or more information: www.keysight.com/find/ezjitplus ezjit complete analysis software (n8823b or option 070 on newscope purchases ? to upgrade from ezjit plus to ezjit complete, order n8813a ? ) ezjit complete includes all of the advanced jitter analysis capabilities of ezjit and ezjit plus, and adds advanced analysis of the vertical noise affecting the ones and zeros of your real-time eye ? decomposition of vertical noise provides key insight into degradation of your eye height ? in providing advanced decomposition of both horizontal jitter and vertical noise components of your signals, ezjit complete represents the most comprehensive analysis software available ? this application is supported on all models and is standard on dsa models ? f or more information: www.keysight.com/ind/ezjitcomplete widest range of debug and compliance software applications: infiniiscan and jitter analysis
13 | keysight | infiniium 9000 series oscilloscopes - data sheet high-speed serial data analysis software (n5384a or option 003 on new scope purchases) quickly validate signal integrity for high-speed serial interfaces with embedded clocks ? recover embedded clocks synchronized with the analog waveform view ? build and validate eye diagrams ? the sda package also includes software-based bit-level triggering and decode for 8b/10b ? this application is supported on all models ? f or more information: www.keysight.com/find/9000_sda vector signal analysis software (89601b) expand the measurement capability of your scope with the 89601b vector signal analysis software ? this advanced dsp-based software takes the digitized signal data from the scope ? then it provides fft-based spectrum analysis and wide-bandwidth digital modulation analysis for wireless communication signals such as wcdma and cdma2000 and wireless networking signals such as 802 ? 1 1 wifi and 802 ? 1 6 wimax ? take advantage of the super-wide bandwidth of your scope to capture and evaluate radar signals ? f or more information: www.keysight.com/find/vsa user-defined function (n5430a or option 010 on new scope purchases) install matlab ? on your scope and add your favorite matlab ? m s cripts as function operators and use them as standard waveform functions ? this application is supported on all models and requires matlab software (not included with udf ? for more information: www.keysight.com/find/udf signal equalization using user-defined function ? use vector signal analysis software to see fft-based spectrum analysis ? recover embedded clocks with serial data analysis (sda) ? widest range of debug and compliance software applications: viewing and analysis
14 | keysight | infiniium 9000 series oscilloscopes - data sheet user-definable application (5467a or option 040 on new scope purchases) rapidly develop your own automated measurements and tests ? this application provides the framework you need to quickly program and automate any single or set of measurements the oscilloscope can make ? the application also provides full control of other keysight instruments and html reporting capabilities ? f or more information: www.keysight.com/find/9000_uda power application (u1882b or option 015 on new scope purchases) keysights power application provides a full suite of power measurements ? make more accurate power-supply efficiency measurements by using an u1880a de-skew fixture to de-skew your voltage and current probes ? t his application is supported on all models ? for more information: www.keysight.com/find/9000_power-app precisionprobe software (n2808a) make more accurate measurements independent of what probes or cables used ? keysights n2808b precisionprobe software characterizes and corrects for the loss in your specific cable or probe ? precisionprobe removes the uncertainty about the input connected to your oscilloscope by allowing you to see its characteristics in less than five minute ? precisionprobe gives you design and debug confidence by allowing you to quickly de-embed probe and cable loss to make more accurate measurements ? for more information: www.keysight.com/find/precisionprobe infiniium offline analysis software (n8900a) wish you could do additional signal viewing, analysis and documentation tasks away from your scope and target system? with keysights infiniiview oscilloscope analysis software you can ? capture waveforms on your scope, save to a file, and open the data record into keysights infiniiview application ? view, analyze, share, and document scope measurements anywhere your pc goes ? quickly characterize and correct for any input to your oscilloscope ? use your scope to quickly make and analyze power measurements ? rapid fpga debug ? quickly automate oscilloscope measurements ? infiniium 9000 series applications and upgrades
15 | keysight | infiniium 9000 series oscilloscopes - data sheet keysight portfolio compare infiniivision infiniium family 6000 x-series 9000 series s-series 90000a series optimized for fastest update rate and lowest price up to 6 ghz measurements up to 4 ghz superior signal integrity up to 8 ghz superior signal integrity up to 13 ghz available bandwidths 500 mhz to 6 ghz 600 mhz to 4 ghz 500 mhz to 8 ghz 2.5 ghz to 13 ghz standard memory depth/ch (2-ch) 4 mpts 40 mpts 100 mpts 40 mpts adc bits 8 8 10 8 bandwidth filters yes 20 mhz (only on 1 m? input) yes. extensive yes. extensive bandwidth correction filters no no yes yes probe inputs 50 ? and 1 m? 50 ? and 1 m? 50 ? and 1 m? 50 ? motherboard and os none. embedded intel core 2 duo. win7 intel i5 quad-core. win7 intel core 2 duo. win7 standard internal drive none hdd removable ssd hdd bnc inputs traditional traditional precision bnc precision bnc mso models yes yes yes no frame volume comparison 1/2 x x x 2x infiniium s-series blends high-performance oscilloscope capability with a wide range general-purpose features ?
16 | keysight | infiniium 9000 series oscilloscopes - data sheet keysight infiniium 9000 series oscilloscopes 15 xga display makes it easier to view analog, digital and serial signals ? touchscreen display comes standard - for mouse-free operation ? drag-and-drop measurements from the measurement bar provide an intuitive way to make a measurement on a particular cycle of your waveform ? mixed-signal oscilloscope (mso) models seamlessly integrate four analog scope channels with 16 digital channels ? comprehensive built-in information system gives you fast answers to your questions ? the task-oriented setup guide provides step-by- step instructions for several measurement procedures ? xga and dvi video output port lets you connect to an external monitor ? standard usb and lan ports provide pc and printer connectivity ? trig in/out ports provide an easy way tosyn - chronize your scope to other instruments ? built-in 10-mhz reference in/out port synchronizes multiple measurement instruments in a system ? aux out for calibration
17 | keysight | infiniium 9000 series oscilloscopes - data sheet pressing horizontal delay knob sets the delay to zero ? a zoom button provides quick access to two screen-zoom modes ? quick access to fine/ vernier control by pressing the horizontal and vertical sensitivity knobs ? autoprobe interface automatically configures the attenuation ratio of the probe and provides probe power for keysights active probes ? built-in usb ports makes it easy to save your work and update your system software quickly ? dedicated single acquisition button provides better control to capture a unique event ? megazoom instant response and optimum resolution allows you to pan and zoom quickly ? autoscale lets you rapidly display any analog or digital active signals, automatically setting the vertical, horizontal and trigger controls for the best display, while optimizing memory ? digital channel button provides quick setup access ? serial decode button enables quick setup access ? dedicated per-channel front panel controls make it easy to access the vertical and horizontal scaling and offset ? accessory pouch detaches easily ?
18 | keysight | infiniium 9000 series oscilloscopes - data sheet connectivity industry compatibility export screen shots and waveforms in numerous industry-standard formats ? in addition, the 9000 series supports compatibility with the following: C matlab basic and advanced (add as 061 and 062 on new scope orders) C ivi com driver for application development environments such as visual studio, keysight vee, ni labview and matlab instrument control toolbox ? www.keysight.com/find/adn C intuilink tool bars and data capture ? www.keysight.com/find/intuilink C lxi class c including built-in web control C ni labview pnp and ivi drives www.keysight.com/find/ni9404 probing each infiniium 9000 series oscilloscope ships with four n2873a 10:1 divider passive probes and probe accessory pouch ? with both 50 ? and 1 m? inputs, infiniium 9000 series scopes support a wide range of probes, including keysights infiniimax and infiniimode series probes ? keysight offers an innovative family of probes that are engineered for signal access and measurement accuracy ? whether youre looking for simple passive probes, the high bandwidth and low loading of an active probe, or specialty probes for current or high voltage, we can meet your needs ? our innovative accessories allow reliable connection to challenging components like small pitch devices, surface mount ics, and ddr bga packages C even hands free! connectivity and probing recommended optional active probes dso/mso9404a 1132a infiniimax 5 ghz probe n2752a infiniimode 6 ghz probe dso/mso9254a 1131a infiniimax 3.5 ghz probe n2751a infiniimode 3.5 ghz probe dso/mso9104a n2796a 2 ghz single-ended probe 1130a infiniimax 1.5 ghz probe n2750a infiniimode 1.5 ghz probe dso/mso9064a n2795a 1 ghz single-ended probe n2750a infiniimode 1.5 ghz probe all n7020a 2 ghz power rail probe with offset up to 24 v n7040a ac current probe 23 mhz, 3 ka n7041a ac current probe 30 mhz, 600 a n7042a ac current probe 30 mhz, 300 a n7026a ac/dc high sensitivity clamp-on current probe 150 mhz, 40 apk with autoprobe to see our entire award-winning portfolio of passive, single-ended active, differential active, and current probes for infiniium oscilloscopes, please view the infiniium oscilloscope probes and accessories selection guide publication number 5968-7141en ?
19 | keysight | infiniium 9000 series oscilloscopes - data sheet infiniium 9000 series performance characteristics vertical: scope channels 9064a 9104a 9254a 9404a analog bandwidth (C3 db) 50 ? 1 600 mhz 1.0 ghz 2.5 ghz 4 ghz 1 m? 500 mhz 500 mhz 500 mhz 500 mhz typical rise time/fall time 10 to 90% at 50 ? 540 ps 253 ps 142 ps 85 ps typical rise time/fall time 20 to 80% at 50 ? 360 ps 174 ps 98 ps 59 ps input channels dso9000 C 4 analog mso9000 C 4 analog + 16 digital input impedance 1 50 ? 2.5%, 1 m? 1% (11pf typical) input sensitivity 3 1 m?: 1 mv/div to 5 v/div 50 ?: 1 mv/div to 1 v/div input coupling 1 m?: ac (3.5 hz), dc 50 ?: dc bandwidth limit 20 mhz on 1 m? input; 500 mhz up to full scope bandwidth in increments of 500 mhz vertical resolution 2, 3 8 bits, 12 bits with averaging channel-to-channel isolation dc to 50 mhz: 50 db > 50 mhz to 2.5 ghz: 40 db > 2.5 ghz to 4 ghz: 25 db dc gain accuracy 1, 2, 3 2% of full scale at full resolution on channel scale 5 oc from cal temp maximum input voltage 1 1 mv: 150 v rms or dc, cat i 250 v (dc + ac) in ac coupling 50 ?: 5 vrms offset range C 1 m? C 50 ? vertical sensitivity 1 mv to < 10 mv/div 10 mv to < 20 mv/div 20 mv to < 100 mv/div 100 mv to < 1 v/div 1 v to 5 v/div available offset 2 v 5 v 10 v 20 v 100 v 12 div or 4 v, whichever is smallest 1 ? denotes warranted specifications, all others are typical ? specifications are valid after a 30-minute warm-up period and 5 c from firmware calibration temperature ? 2 ? input impedance is valid when v/div scaling is adjusted to show all waveform vertical values within scope display ? 3 ? 9huwlfdouhvroxwlrqiruelwv riixoovfdohiruelwv riixoovfdohlqsxw)xoovfdohlvghilqhgdvyhuwlfdoglylvlrqv0djqlilfdwlrqlv used below 10 mv/div, full-scale is defined as 80 mv ? the major scale settings are 5 mv, 10 mv, 20 mv, 50 mv, 100 mv, 200 mv, 500 mv, 1 v ? 0l qsxw)xoovfdohlvghoqhgdvyhuwlfdoglylvlrqv0djqlofdwlrqlvxvhgehorzp9glyixoovfdohlvghoqhgdvp97khpdmruvfdohvhwwlqjvduh 5 mv, 10 mv, 20 mv, 50 mv, 100 mv, 200 mv, 500 mv, 1 v, 2 v, 5 v ?
20 | keysight | infiniium 9000 series oscilloscopes - data sheet infiniium 9000 series performance characteristics (continued) vertical: digital channels on all mso models input channels 16 digital channels threshold groupings 16 digital channels pod 2: d15 to d8 threshold selections ttl (1.4v), cmos, (5.0 v, 3.3 v, 2.5 v), ecl (1.3 v), pecl (3.7 v), user defined ( 8.00 v in 100 mv increments) maximum input voltage 40 v peak cat i threshold accuracy (100 mv + 3% of threshold setting) input dynamic range 10 v about threshold minimum input voltage swing 500 mv peak-to-peak input impedance (flying leads) 100 k? 2% (~ 8 pf) at probe tip resolution 1 bit analog bandwidth 400 mhz 1 ? denotes warranted specifications, all others are typical ? specifications are valid after a 30-minute warm-up period and 5 c from firmware calibration temperature ? 2 ? vertical resolution for 8 bits = 0 ? 4 % of full scale, for 12 bits = 0 ? 0 24% of full scale ? 3 ? lqsxw)xoovfdohlvghilqhgdvyhuwlfdoglylvlrqv0djqlilfdwlrqlvxvhgehorzp9glyixoovfdohlvghilqhgdvp97khpdmruvfdohvhwwlqjvduh 5 mv, 10 mv, 20 mv, 50 mv, 100 mv, 200 mv, 500 mv, 1 v ? 0 lqsxw)xoovfdohlvghoqhgdvyhuwlfdoglylvlrqv0djqlofdwlrqlvxvhgehorzp9glyixoovfdohlvghoqhgdvp97khpdmruvfdohvhwwlqjvduh 5 mv, 10 mv, 20 mv, 50 mv, 100 mv, 200 mv, 500 mv, 1 v, 2 v, 5 v ? rms noise floor (v rms ac ) 9064a 9104a 9254a 9404a volts/div 10 mv 213 uv 240 uv 273 uv 402 uv 20 mv 470 uv 481 uv 445 uv 627 uv 50 mv 1.15 mv 1.24 mv 1.22 mv 1.67 mv 100 mv 2.37 mv 2.43 mv 2.54 mv 3.17 mv 200 mv 4.65 mv 4,85 mv 5.06 mv 6.18 mv 500 mv 11.8 mv 12.3 mv 12.2 mv 15.8 mv 1 v 23.9 mv 24.3 mv 25.2 mv 31.5 mv vertical: scope channels (continued) offset accuracy 1, 3 (1.25% of channel offset +1% of full scale + 1 mv) dynamic range 1 m?: 8 div from center screen 50 ?: 8 div from center screen dc voltage measurement accuracy 2 dual cursor [(dc gain accuracy)+(resolution)] single cursor [(dc gain accuracy)+(offset accuracy)+(resolution/2)] v increments)
21 | keysight | infiniium 9000 series oscilloscopes - data sheet jitter measurements floor 2, 3 time interval error 4 period jitter n-cycle, cycle-cycle jitter 9064 1.0 1.0 9104 1.0 0.5 9254 .95 1.1 9404 .95 1.2 9064 .75 9104 .65 9254 .75 9404 .80 9064 1.8 9104 1.4 9254 1.9 9404 2.0 1 ? denotes warranted specifications, all others are typical ? specifications are valid after a 30-minute warm-up period and 5 c from firmware calibration temperature ? 2 ? noise is the displayed noise floor ? slewrate is the displayed slew rate of the signal at the threshold crossings ? sample rate = max, sin(x)/x interpolation enabled ? 3 ? measurement threshold = fixed voltage at 50% level ? 4 ? time ranges 10 s. 5 ? values represent time error between two edges on a single channel ? standard deviation value refers to the standard deviation of 256 consecutive measurements performed using an individual instrument ? reading is the displayed dtma measurement value ? delta-time measurement accuracy 2, 3, 4, 5 absolute averaging disabled absolute > 256 averages standard deviation averaging disabled standard deviation > 256 averages 9064 4.8 20 9104 4.8 15 9254 4.0 15 9404 5.0 20 9064 .33 .1 9104 .33 .05 9254 .33 .10 9404 .35 .15 9064 .75 9104 .65 9254 .75 9404 .80 horizontal channel-to-channel skew (digital) 2 ns typical main time base range qv horizontal position range 5 ps/div to 20 s/div delayed sweep range 1 ps/div to current main time base setting resolution 1 ps modes main, delayed, roll (200 ms to 20 sec) reference positions left, center, right channel deskew 1 ms to +1 ms range time scale accuracy (internal reference) (external reference clock = off) +rulrqwdowlphedvhvhwwlq+rulrqwdowlphedvhvhwwlqhduvvlqfhfdoleudwlrqssp infiniium 9000 series performance characteristics (continued)
22 | keysight | infiniium 9000 series oscilloscopes - data sheet infiniium 9000 series performance characteristics (continued) acquisition 9104, 9254, 9404 9064 maximum real-time sample rate 4 ch x 10 gs/s or 2 ch x 20 gs/s 4 ch x 5 gsa/s or 2 ch x 10 gsa/s memory depth per channel standard 20 mpts on 4 channels, 40 mpts on 2 channels option 50m 50 mpts on 4 channels, 100 mpts on 2 channels option 100 100 mpts on 4 channels, 200 mpts on 2 channels option 200 200 mpts on 4 channels, 400 mpts on 2 channels option 500 500 mpts/250 mpts on 4 channels, 1 gpts/500 mpts on 2 channels (single/repetitive mode) sampling modes real-time real-time with peak detect real-time with high resolution (user selectable to 9-, 10-, 11-, or 12-bits of resolution) real-time with roll mode (200 ms to 20 sec.) equivalent-time (1.0 ps fine interpolator resolution yields a maximum effective sample rate of 1,000 gsa/s) segmented memory (1 ps time stamp resolution between segments) maximum time between triggers is 562,950 seconds (6.5 days) re-arm time (minimum time between trigger events) is 4.5 s with analog channels, 5.8 s with digital channels on acquisition: digital channels maximum real time sample rate 2 gsa/s maximum memory depth per channel 128/64 mpts with 2 gsa/s. 64/32 mpts with sampling < 2 gsa/s (single/repetitive mode) minimum width glitch detection 2 ns trigger: scope channels trigger sources channel 1, channel 2, channel 3, channel 4, aux, and line sensitivity 1 m? input, edge trigger dc to 500 mhz: 0.6 div 50 ? dc to 2 ghz, 0.5 div 2 ghz to 4 ghz: 1.0 div auxiliary dc to 700 mhz: 300 mvp-p trigger level range 4 div from center screen (50 ?) channel 1, 2, 3 or 4 8 div from center screen with max of 8 v (1 m?) auxiliary 5 v (50 ? up to 500 mhz with at least 500 mv signal swing) sweep modes auto, triggered, single display jitter (displayed trigger jitter) 1, 2 9064 .50 9104 .35 9254 .50 9404 .40 trigger holdoff range 100 ns to 10 s fixed and random trigger actions specify an action to occur, and the frequency of the action, when a trigger condition occurs actions include: e-mail on trigger and execute multipurpose user settings trigger coupling 1 m?: dc, ac, (10 hz) low frequency reject (50 khz high pass filter), high frequency reject (50 khz low pass filter) 1 ? internal edge trigger mode ? trigger threshold = fixed voltage at 50% level ? the slew rate independent value in the formula represents the traditional trigger jit ter ? 2 ? display jitter example ? at 100 mv/div typical noise values are 3 ? 2 m v rms for 9404 models, 2 ? 5 m v rms for 9254a models, and 2 ? 4 m v rms for 9104a models ? for slew rate of 500 mvpp sin wave with frequency equal to max analog bandwidth of each model, typical display jitter is ? 9 5 ps rms for 9404a models, ? 9 7 ps for 9254a models, and 1 ? 7 p s rms for 9104a models ? memory depth: 20 m 50 m 100 m 200 m 500 m 1 g 2 g max # of segments: 4096 8192 16384 32768 65536 131072 131072 filters
23 | keysight | infiniium 9000 series oscilloscopes - data sheet infiniium 9000 series performance characteristics (continued) trigger: digital channels mso models threshold range (user defined) 8.0 v in 100-mv increments threshold accuracy (100 mv + 3% of threshold setting) measurements and math waveform measurements (can be made on either min or zoom window with up to 10 simultaneous measurements with statistics) C voltage (scope channels) peak-to-peak, minimum, maximum, average, rms, amplitude, base, top, overshoot, v overshoot, preshoot, v preshoot, upper, middle, lower, crossing point voltage, pulse top, pulse base, pulse amplitude C time (digital channels) period, frequency, positive width, negative width, duty cycle, delta time C time (scope channels) rise time, fall time, period, frequency, positive width, negative width, duty cycle, tmin, tmax, tvolt, channel-to-channel delta time, channel-to-channel phase , count pulses, burst width, burst period, burst interval, setup time, hold time C mixed (scope channels only) area, slew rate C frequency domain fft frequency, fft magnitude, fft delta frequency, fft delta magnitude all timing measurements eye-diagram measurements eye height, eye width, eye jitter, crossing percentage, q factor, and duty-cycle distortion measurement modes C statistics displays the mean, standard deviation, minimum, maximum range, and number of measurement values for the displayed automatic measurements histograms (scope channels) waveform or measurement (histogram on measurement requires ezjit, ezjit+, or ezjit complete option) C source C orientation vertical (for timing and jitter measurements) or horizontal (noise and amplitude change) modes, regions are defined using waveform markers C measurements mean, standard deviation, mean 1, 2, and 3 sigma, median, mode, peak-to-peak, min, max, total hits, peak (area of most hits), x scale hits, and x offset hits waveform math manual markers, track waveform data, track measurements C number of functions 16 C operators operators absolute value, add, am demodulation, average, horizontal gating, butterworth 1 , common mode, differentiate, divide, fft magnitude, fft phase, fir11, high pass filter, integrate, invert, lfe 1 , low pass filter (4th-order bessel thompson filter), magnify, max, min, multiply, rt eye 1 , smoothing, sqrtsumofsquare 1 , square, square root, subtract, versus chartstate (mso models), charttiming (mso models) automatic measurements measure menu access to all measurements, ten measurements can be displayed simultaneously multipurpose front-panel button activates up to ten pre-selected or ten user-defined automatic measurements drag-and-drop measurement toolbar with common measurement icons that can be dragged and dropped onto the measurement toolbar displayed waveforms fft manual markers, track waveform data, track measurements C frequency range dc to 10 ghz (at 20 gsa/s) or 5 ghz (at 10 gsa/s) C frequency resolution resolution = sample rate/memory depth C window modes hanning, flattop, rectangular, blackman harris, force 1 ? requires matlab software ?
24 | keysight | infiniium 9000 series oscilloscopes - data sheet trigger modes on all mso models edge (analog and digital) triggers on a specified slope (rising, falling or alternating between rising and falling) and voltage level on any channel. edge transition (analog) trigger on rising or falling edges that cross two voltage levels in > or < the amount of time specified. edge transition setting from 250 ps. edge then edge (time) (analog and digital) the trigger is qualified by an edge. after a specified time delay between 10 ns to 10 s, a rising or falling edge on any one selected input will generate the trigger. edge then edge (event) (analog and digital) the trigger is qualified by an edge. after a specified delay between 1 to 16,000,000 rising or falling edges, another rising or falling edge on any one selected input will generate the trigger. glitch (analog and digital) triggers on glitches narrower than the other pulses in your waveform by specifying a width less than your narrowest pulse and a polarity. glitch range settings equal pulse width settings. line triggers on the line voltage powering the oscilloscope. pulse width (analog and digital) trigger on a pulse that is wider or narrower than specified. C 4 ghz model minimum detectable pulse width: 125 ps for analog channels, 1 ns for digital channels. pulse width range settings: 250 ps to 10 s for analog channels, 2 ns to 10 s for digital channels. C 2.5 ghz model minimum detectable pulse width: 200 ps for analog channels, 1 ns for digital channels. pulse width range settings: 350 ps to 10 s for analog channels, 2 ns to 10 s for digital channels. C 1 ghz and 600 mhz model minimum detectable pulse width: 500 ps for analog channels, 1 ns for digital channels. pulse width range settings: 700 ps to 10 s for analog channels, 2 ns to 10 s for digital channels. runt (analog) triggers on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again. runt settings equal pulse width settings. timeout (analog and digital) trigger when a channel stays high, low, or unchanged for too long. timeout settings equal pulse width settings. pattern/pulse range (analog and digital) triggers when a specified logical combination of the channels is entered, exited, present for a specified period of time or is within a specified time range or times out. each channel can have a value of high (h), low (l) or dont care (x). state (analog and digital) pattern trigger clocked by the rising, falling or alternating between rising and falling edge of one channel. setup/hold (analog) triggers on setup, hold, or setup and hold violations in your circuit. requires a clock and data signal on any two inputs (except aux or line) channels as trigger sources. setup and/or hold time must then be specified. window (analog) trigger on entering, exiting, or inside specified voltage range. video (analog) ntsc, pal-m(525/60), pal, secam(625,50) edtv(480p/60), edtv(576/50), hdtv(720p/60), hdtv(720p/50) hdtv(1080i/60). serial (analog and digital) requires specified serial software option, i 2 c, spi, can, lin,flexray, rs-232/uart, jtag, usb, pcie, mipi d-phy, generic 8b/10b. zone-qualified requires infiniiscan software option. sw-based triggering across up to 8 user-drawn zones. for each zone, user specifies must intersect or must not intersect. zones can be drawn on multiple channels and combined using boolean expressions. infiniium 9000 series performance characteristics (continued)
25 | keysight | infiniium 9000 series oscilloscopes - data sheet infiniium 9000 series performance characteristics (continued) display display 15 inch color xga tft-lcd with touch screen display intensity grayscale 64-level intensity-graded display C resolution 1024 pixels horizontally x 768 pixels vertically C annotation up to 12 labels, with up to 100 characters each, can be inserted into the waveform area C grids can display 1, 2 or 4 waveform grids C waveform styles connected dots, dots, variable persistence, infinite persistence, color graded infinite persistence. includes up to 64 levels of intensity-graded waveform waveform update rate (10 gs/s, 50 ns/div, sin(x)/x: on) segmented mode: maximum up to 250,000 waveforms/sec real time mode: C typical of 700 waveforms/sec with 1 kpts memory C typical of 230 waveforms/sec with 100 kpts memory C typical of 130 waveforms/sec with 1 mpts memory computer system and peripherals, i/o ports computer system and peripherals C operating system windows 7 embedded standard C cpu intel ? core 2 duo, m890, 3.0 ghz microprocessor C pc system memory 4 gb C drives 250-gb internal hard drive (optional removable hard drive) C peripherals optical usb mouse and compact keyboard supplied. all infiniium models support any windowscompatible input device with a ps/2 or usb interface. file types C waveforms compressed internal format (*.wfm), comma separated values (*.csv), .hdf5, .bin, tab separated values (*.tsv), ability to save .osc (composite including both setup and waveform. and y value files (*.txt) C images bmp, tiff, gif, png or jpeg i/o ports C lan rj-45 connector, supports 10base-t, 100base-t, and 1000base-t. enables web-enabled remote control, e-mail on trigger, data/file transfers and network printing C rs-232 (serial) 9-pin, com1, printer and pointing device support C ps/2 two ports. supports ps/2 pointing and input devices. C usb 2.0 hi-speed three 2.0 high-speed ports on front panel plus four ports on side panel. allows connection of usb peripherals like storage devices and pointing devices while the oscilloscope is on. one device port on side for instrument control. C video output 15 pin xga on side of scope, full output of scope display or dual monitor video output, dvi C auxiliary output dc ( 2.4 v); square wave ~755 hz with ~200 ps rise time time base reference output 10 mhz, amplitude into 50 ohms: 800 mv pp to 1.26 v pp (4 dbm 2 db) if derived from internal reference. tracks external reference input amplitude 1 db if applied and selected. time base reference output must be 10 mhz, input z = 50 ohms. minimum 500 mv pp (C2 dbm), maximum 2.0 v pp (+10 dbm) lxi compliance lxi class c
26 | keysight | infiniium 9000 series oscilloscopes - data sheet infiniium 9000 series performance characteristics (continued) general characteristics temperature operating 5 to + 40 c non-operating C40 to + 65 c humidity operating up to 95% relative humidity (non-condensing) at +40 c non-operating up to 90% relative humidity at +65 c altitude operating up to 4,000 meters (12,000 feet) non-operating up to 15,300 meters (50,000 feet) vibration operating random vibration 5 to 500 hz, 10 minutes per axis, 0.21 g(rms) non-operating random vibration 5 to 500 hz, 10 minutes per axis, 2.09 g(rms); resonant search 5 to 500 hz swept-sine, 1 octave/minute sweep rate, 0.5 g (0-peak), 5 minute resonant dwells at 4 resonances per axis power 100 to 120 v, 10% 50/60/400 hz 100 to 240 v, 10% 50/60 hz max power dissipated: 375 w typical operator noise 30 db at front of instrument weight net: 11.8 kg (26 lbs.) shipping: 17.8 kg (39 lbs.) dimensions (with feet retracted) height: 12.9 in (33 cm); width: 16.8 in (43 cm); depth: 9 in (23 cm) safety meets iec1010-1 second edition, certified to ul61010-1 and can/csa-c22.2 no 61010-1 second edition (iec61010-1:2001, mod)
27 | keysight | infiniium 9000 series oscilloscopes - data sheet infiniium 9000 series ordering information accessories included: all models ship standard with: four n2873a 500 mhz passive probes, probe accessory pouch (mounts on rear of instrument), keysight i/o libraries suite 15 ? 0 , localized power cord, front panel cover, keyboard, mouse, and stylus ? user guide and programmers guide ship on oscilloscope hard drive ? service guide available on keysight ? c om ? mso models additionally ship with channel flying lead set logic probe, mso cable and calibration fixture ? mount your 9000 series scope in an 8u high, 19 (487 mm) wide rack with option icm ? model analog bandwidth analog sample rate 1 (4 ch/2 ch) standard memory 1 (4 ch/2 ch) scope channels logic channels dso9064a 600 mhz 5 gsa/s/10 gsa/s 20 mpts/40 mpts 4 mso9064a 600 mhz 5 gsa/s/10 gsa/s 20 mpts/40 mpts 4 16 dso9104a 1 ghz 10 gsa/s/20 gsa/s 20 mpts/40 mpts 4 mso9104a 1 ghz 10 gsa/s/20 gsa/s 20 mpts/40 mpts 4 16 dso9254a 2.5 ghz 10 gsa/s/20 gsa/s 20 mpts/40 mpts 4 mso9254a 2.5 ghz 10 gsa/s/20 gsa/s 20 mpts/40 mpts 4 16 dso9404a 4 ghz 10 gsa/s/20 gsa/s 20 mpts/40 mpts 4 mso9404a 4 ghz 10 gsa/s/20 gsa/s 20 mpts/40 mpts 4 16 1 ? in 2-channel mode, maximum sample rate and memory depth double ? how to configure an infiniium 9000 series 1 ? choose needed bandwidth 2 ? choose mso or dso 3 ? choose desired software applications 4 ? choose memory depth upgrade 5 ? choose any additional probes and accessories additional options and accessories option a6j ansi z540 compliant calibration n2902b or option 1cm (8u) 9000 series oscilloscope rackmount kit option 801 removable solid state drive n2746a (requires option 801) additional solid state drive windows 7 embedded standard gemstar 5000 custom-molded case available from www.gemstarmfg.com n4865a gpib to lan adapter quickly remove your solid state drive for additional security with option 801 ? memory options memory per scope channel (4-channel/2-channel mode) factory-installed option for new scope purchases 20 mpts/40 mpts standard 50 mpts/100 mpts dso/mso9000a-50m 100 mpts/200 mpts dso/mso9000a-100 200 mpts/400 mpts dso/mso9000a-200 500 mpts/1 gpts dso/mso9000a-500
28 | keysight | infiniium 9000 series oscilloscopes - data sheet infiniium 9000 series ordering information (continued) sw applications factory-installed option for new scope purchases user-installed stand- alone product number user-installed floating license (n5435a option) rs-232/uart triggering and decode 001 n5462b 031 ezjit jitter analysis software 002 e2681a 002 high-speed sda and clock recovery 003 n5384a 003 ezjit plus jitter analysis software 004 n5400a 001 usb triggering and decode 005 n5464b 034 pci express 1.1 triggering and decode 006 n5463b 032 i2c/spi triggering and decode 007 n5391b 006 i 2 s protocol triggering and decode n8811a-1fp n8811a-1fp 105 can, lin, can-fd, and flexray triggering and decode 008 n8803c 103 infiniiscan 009 n5415b 004 user-defined function 010 n5430a 005 infiniisim signal equalization 012 n5461a 025 infiniisim basic signal de-embedding 013 n5465a 001 026 infiniisim advanced signal de-embedding 014 n5465a 002 027 power measurement application software 015 u1882b rs-232, spi and i 2 c triggering and decode bundle 018 n8800b mipi d-phy triggering and decode 019 n8802b 036 spmi protocol trigger and decode software n8 8 45a-1fp n8845a 114 ethernet compliance 021 n5392b 008 usb2.0 compliance 029 N5416A 017 ddr1 and lpddr compliance 031 u7233a 021 ddr2 and lpddr2 compliance 032 n5413b 016 ddr3 compliance 033 u7231b 020 mipi d-phy compliance 035 u7238b 022 sata1 (1.5 gb/s triggering and decode) 038 n8801a 035 user definable application 040 n5467b jtag (ieee 1149.1) triggering and decode 042 n8817b 038 usb hsic compliance test 043 u7248b 042 digrf protocol decode 045 n8807b 047 svid protocol triggering and decode 046 n8812b 054 communication mask test kit e2625a matlab basic 061 matlab advanced 062 hdmi 1.4 (up to 740 mbp/s) n5399d 10gbase-t ethernet compliance u7236b precision probe n2808a 044 emmc compliance 064 n6465b 061 broadr-reach compliance 065 n6467b 062 ezjit complete jitter analysis software 070 n8823b 067 most compliance 073 n6466b 068 mipi rffe protocol 075 n8824b energy efficient ethernet n5392b mg base-t u7236b
29 | keysight | infiniium 9000 series oscilloscopes - data sheet upgrades dso to mso upgrades n2901e upgrade your existing dso to an mso model in 5 minutes ? the upgrade kit turns on all mso capability and includes an mso cable, 16-channel lead set with grabbers, an mso-enabled sticker, and a digital-analog deskew fixture ? n2901e upgrade includes: C qty(1) e 5383a flying lead probe (listed as 01650-61609 probe tip) C qty(1) 5 4904-61622 mso ribbon cable (connects e5383a to scope) C qty(1) 5 090-4833 grabber kit assembly (pack of 20 ic clips) C qty(1) 5 959-9334 probe ground 2 (pack of 5) C qty(1) m so enabled sticker for the back of the scope used for calibration of mso channels C qty(1) 1 250-3817 bnc-probe-tip adapter C qty(1) 1 250-0080 bnc(f-f) barrel additional acquisition memory (n2900a or options 50, 100, 200, and 500 on new scope purchase) increase memory depth to capture longer time periods and maintain faster speeds ? memory depth doubles in 2-channel mode ? post-sales upgrades dso mso upgrades n2901e dso to mso upgrade for 9000 and s-series oscilloscopes bandwidth upgrades (done at service centers 1 ) n2905a upgrade to 2.5 ghz bandwidth C option 006, 600 mhz to 2.5 ghz C option 010, 1 ghz to 2.5 ghz n2904a upgrade to 4.0 ghz bandwidth C option 006, 600 mhz to 4 ghz C option 010, 1 ghz to 4 ghz C option 025, 2.5 ghz to 4 ghz memory depth upgrades n2900a depth doubles in 2 channel mode C 2swlrq8sjudghiurp0swvfkwr 50 mpts/ch C 2swlrq8sjudghiurp0swvfkwr 100 mpts/ch C 2swlrq8sjudghiurp0swvfk to 200 mpts/ch C 2swlrq8sjudghiurp0swvfk to 500 mpts/ch operating system upgrades n2753a windows 7 embedded standard for infiniium 9000 scope with windows xp and sn>my50410100 (customer installable) n2754a window 7 embedded standard and m890 motherboard for infiniium 9000 scopes with windows xp and sn 30 | keysight | infiniium 9000 series oscilloscopes - data sheet keysight oscilloscopes multiple form factors from 20 mhz to > 90 ghz | industry leading specs | powerful applications
31 | keysight | infiniium 9000 series oscilloscopes - data sheet www.axiestandard.org advancedtca ? extensions for instrumentation and test (axie) is an open standard that extends the advancedtca for general purpose and semiconductor test ? the business that became keysight was a founding member of the axie consortium ? atca ? , advancedtca ? , and the atca logo are registered us trademarks of the pci industrial computer manufacturers group ? www.lxistandard.org lan extensions for instruments puts the power of ethernet and the web inside your test systems ? the business that became keysight was a founding member of the lxi consortium ? www.pxisa.org pci extensions for instrumentation (pxi) modular instrumentation delivers a rugged, pc-based high-performance measurement and automation system ? learn more at www.keysight.com/find/software start with a 30-day free trial ? www.keysight.com/find/free_trials download your next insight keysight software is downloadable expertise ? from first simulation through first customer shipment, we deliver the tools your team needs to accelerate from data to information to actionable insight ? C electronic design automation (eda) software C application software C programming environments C productivity software
32 | keysight | infiniium 9000 series oscilloscopes - data sheet this information is subject to change without notice ? ? keysight technologies, 2013 - 2017 published in usa, november 7, 2017 5990-3746en www.keysight.com evolving since 1939 our unique combination of hardware, software, services, and people can help you reach your next breakthrough ? we are unlocking the future of technology ? from hewlett-packard to agilent to keysight ? mykeysight www.keysight.com/find/mykeysight a personalized view into the information most relevant to you ? http://www.keysight.com/find/emt_product_registration register your products to get up-to-date product information and find warranty information ? keysight services www.keysight.com/find/service keysight services can help from acquisition to renewal across your instruments lifecycle ? our comprehensive service offeringsone- stop calibration, repair, asset management, technology refresh, consulting, training and morehelps you improve product quality and lower costs ? keysight assurance plans www.keysight.com/find/assuranceplans up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements ? keysight channel partners www.keysight.com/find/channelpartners get the best of both worlds: keysights measurement expertise and product breadth, combined with channel partner convenience ? pci-sig ? , pcie ? and the pci express ? are us registered trademarks and/or service marks of pci-sig ? mipi ? service marks and logo marks are owned by mipi alliance, inc ? and any use of such marks by keysight technologies is under license ? other service marks and trade names are those of their respective owners ? www.keysight.com/find/9000 for more information on keysight technologies products, applications or services, please contact your local keysight office ? the complete list is available at: www.keysight.com/find/contactus americas canada (877) 894 4414 brazil 55 11 3351 7010 mexico 001 800 254 2440 united states (800) 829 4444 asia pacific australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 11 2626 japan 0120 (421) 345 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 other ap countries (65) 6375 8100 europe & middle east austria 0800 001122 belgium 0800 58580 finland 0800 523252 france 0805 980333 germany 0800 6270999 ireland 1800 832700 israel 1 809 343051 italy 800 599100 luxembourg +32 800 58580 netherlands 0800 0233200 russia 8800 5009286 spain 800 000154 sweden 0200 882255 switzerland 0800 805353 opt ? 1 (de) opt ? 2 (fr) opt ? 3 (it) united kingdom 0800 0260637 for other unlisted countries: www.keysight.com/find/contactus (bp-9-7-17) dekra certified iso9001 quality management system www.keysight.com/go/quality keysight technologies, inc ? dekra certified iso 9001:2015 quality management system


▲Up To Search▲   

 
Price & Availability of N5416A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X